RBK-6000-ZL30
The combustible gas leak alarm and toxic gas leak alarm produced by our company have complete product qualifications. Qualification of products * fire certification, measurement certification, explosion-proof certification and product quality liability insurance! The qualifications of our company's products are issued by the relevant departments of the country and it is a recognized qualification. If there is a fire department inspection, please feel free to purchase!
Product Overview The controller obtains the detector information through query, and after high-speed CPU data processing, displays the corresponding concentration and state of the detector through the LCD and outputs the corresponding control signal. This product design follows the national standard GB16808-2008. The appearance of the controller is beautiful, the display interface is clear, and the operation is simple. The product machine adopts a modular structure design and is easy to maintain.
Features:
Work mode M-BUS2 bus communication, load capacity ≤ 60 way.
High reliability The CPU uses a 16-bit microcontroller, which is fast and reliable.
It is easy to operate and can calibrate and calibrate the online detector remotely; it can manually output the signal.
High security multiple password protection. Different operating levels, different passwords, and high security.
Intuitive and clear display with high-brightness LCD display, real-time display of master time, alarm, fault records. Large-capacity alarm, open and shut down records, history records are not lost when power is off.
A variety of signal output 2 sets of switch output. Through the connection module can choose to output 4-20mA, GPRS/GSM, UDP/TCP/HTTP signals.
Easy to install special mounting brackets, convenient installation on site.
The main technical parameters of the product:
Structure weight: 3.4
Material: Q235+ABS
Size: 320mm×250mm×94mm
Electrical supply voltage: AC220V±15%, 50-60Hz
Maximum power: 10W
Signal input: M-BUS signal relay capacity: 5A/220V
Storage capacity: Alarm records: 1000 boot records: 100 shutdown records: 100 certifications * Department: Fire Electronic Product Conformity Assessment Center Application Standard: GB16808-2008
Environmental IP Level: IP30
Working temperature: -20°C~55°C
Humidity range: 10% RH to 95% RH
Pressure range: 86Kpa~106Kpa
Storage temperature: -10°C~50°C
Installation method: wall-mounted installation alarm mode: sound and light alarm; sound alarm: sub-fault alarm, concentration alarm two different sounds; light alarm: display LED system LED status (alarm, fault), power status (main Electrical fault, backup fault, charging fault)
Alarm sound: ≥75dB
error code:
"E0" display board and output board do not communicate "E1" Current address Detector sensor failure "E2" Current address detector Communication failure "E3" Current address detector Memory chip failure "E6" Clock chip failure "E7" Memory chip failure "E8" Connection Detector for Circuit Short Product Installation:
Installation position: non-explosion-proof occasions, duty room or place where personnel often enter and install height:
Please mark the wall with 2 fixing holes with a diameter of 5mm (180mm horizontal distance).
Fasten the mounting plate to the wall.
Hang the mounting hook on the back of the controller to the mounting plate.
Our company's products are simple, practical, and easy to install. We will accompany the product with the product manual to help you understand this product in detail. There are product manuals in hand, do not worry about any situation, they can simply operate.
The combustible gas leak alarm and toxic gas leak alarm produced by our company have complete product qualifications. Qualification of products * fire certification, measurement certification, explosion-proof certification and product quality liability insurance! The qualifications of our company's products are issued by the relevant departments of the country and it is a recognized qualification. If there is a fire department inspection, please feel free to purchase!
Product Overview The controller obtains the detector information through query, and after high-speed CPU data processing, displays the corresponding concentration and state of the detector through the LCD and outputs the corresponding control signal. This product design follows the national standard GB16808-2008. The appearance of the controller is beautiful, the display interface is clear, and the operation is simple. The product machine adopts a modular structure design and is easy to maintain.
Features:
Work mode M-BUS2 bus communication, load capacity ≤ 60 way.
High reliability The CPU uses a 16-bit microcontroller, which is fast and reliable.
It is easy to operate and can calibrate and calibrate the online detector remotely; it can manually output the signal.
High security multiple password protection. Different operating levels, different passwords, and high security.
Intuitive and clear display with high-brightness LCD display, real-time display of master time, alarm, fault records. Large-capacity alarm, open and shut down records, history records are not lost when power is off.
A variety of signal output 2 sets of switch output. Through the connection module can choose to output 4-20mA, GPRS/GSM, UDP/TCP/HTTP signals.
Easy to install special mounting brackets, convenient installation on site.
The main technical parameters of the product:
Structure weight: 3.4
Material: Q235+ABS
Size: 320mm×250mm×94mm
Electrical supply voltage: AC220V±15%, 50-60Hz
Maximum power: 10W
Signal input: M-BUS signal relay capacity: 5A/220V
Storage capacity: Alarm records: 1000 boot records: 100 shutdown records: 100 certifications * Department: Fire Electronic Product Conformity Assessment Center Application Standard: GB16808-2008
Environmental IP Level: IP30
Working temperature: -20°C~55°C
Humidity range: 10% RH to 95% RH
Pressure range: 86Kpa~106Kpa
Storage temperature: -10°C~50°C
Installation method: wall-mounted installation alarm mode: sound and light alarm; sound alarm: sub-fault alarm, concentration alarm two different sounds; light alarm: display LED system LED status (alarm, fault), power status (main Electrical fault, backup fault, charging fault)
Alarm sound: ≥75dB
error code:
"E0" display board and output board do not communicate "E1" Current address Detector sensor failure "E2" Current address detector Communication failure "E3" Current address detector Memory chip failure "E6" Clock chip failure "E7" Memory chip failure "E8" Connection Detector for Circuit Short Product Installation:
Installation position: non-explosion-proof occasions, duty room or place where personnel often enter and install height:
Please mark the wall with 2 fixing holes with a diameter of 5mm (180mm horizontal distance).
Fasten the mounting plate to the wall.
Hang the mounting hook on the back of the controller to the mounting plate.
Our company's products are simple, practical, and easy to install. We will accompany the product with the product manual to help you understand this product in detail. There are product manuals in hand, do not worry about any situation, they can simply operate.
The cup brushes remove rust, paint, dust and burrs from surfaces such as metals and wood, and can also be used to level weld spatter. Wire grinder brush for drill can be used for surface adhesion treatment before painting, spray coating and electroplating. It can also be used for surface paint peeling and grinding.Behappy cup brushes are used to remove adhesive residues, hard lime, rust, paint and excess rubber
Cup Brushes,Wire Brus,Steel Wire Brush,Polishing Brush
Behappy Crafts (suzhou)Co.,Ltd , https://www.craftsbehappy.com